Safety Data Sheet (SDS)

Loading...

41.0

Page 1/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

* 1 Identification · Product identifier · Trade name: Precision Calibration Gas Mixture · Product number: G-615 · Relevant identified uses of the substance or mixture and uses advised against Used for calibration of gas measuring devices. Not suitable for human consumption. · Product description Calibration gas mixture consisting of Methane, Oxygen and Nitrogen. · Details of the supplier of the safety data sheet · Manufacturer/Supplier: Gasco Affiliates, LLC 320 Scarlett Blvd. Oldsmar, Fl 34677 TELEPHONE NUMBER: (800) 910-0051 FAX NUMBER: (866) 755-8920 E-MAIL: [email protected] · Emergency telephone number: Inside the US: 1-800-424-9300 (CHEMTREC, 24 hours) Outside the US: 1-703-527-3887 (CHEMTREC, 24 hours) * 2 Hazard(s) identification · Classification of the substance or mixture GHS04 Gas cylinder Press. Gas H280 Contains gas under pressure; may explode if heated. · Label elements · GHS label elements The product is classified and labeled according to the Globally Harmonized System (GHS). · Hazard pictograms

GHS04 · Signal word Warning · Hazard-determining components of labeling: Nitrogen Methane · Hazard statements Contains gas under pressure; may explode if heated. · Precautionary statements Protect from sunlight. Store in a well-ventilated place. · Unknown acute toxicity: 100 percent of the mixture consists of ingredient(s) of unknown toxicity. (Contd. on page 2)

41.0

Page 2/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture · Classification system: · NFPA ratings (scale 0 - 4)

0

0

Health = 0 Fire = 0 Reactivity = 0

0

· HMIS-ratings (scale 0 - 4) HEALTH

0

FIRE

0

REACTIVITY 0

Health = 0 Fire = 0 Reactivity = 0

· Hazard(s) not otherwise classified (HNOC): None known * 3 Composition/information on ingredients · Chemical characterization: Mixtures · Description: Mixture of substances listed below with nonhazardous additions. · Dangerous Components: CAS: 7727-37-9 Nitrogen Press. Gas, H280; Simple Asphyxiant RTECS: QW 9700000 CAS: 7782-44-7 Oxygen Oxid. Gas 1, H270; Press. Gas, H280 CAS: 74-82-8 Methane Flam. Gas 1, H220; Press. Gas, H280 RTECS: PA 1490000

75.6 - 97.9999% 2 - 20.9% 0.0001 - 3.5%

* 4 First-aid measures · Description of first aid measures · General information: Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident. · After inhalation: Supply fresh air. If required, provide artificial respiration. Consult doctor if symptoms persist. In case of unconsciousness, place patient securely on side position for transportation. · After skin contact: Generally the product does not irritate the skin. In cases of contact with liquified material, frostbite may occur. Immerse frostbite in cool-warm water and seek medical attention. · After eye contact: Not anticipated under normal use. If irritation occurs thoroughly wash the exposed area and discontinue use. Seek medical attention if any adverse effect occurs. · After swallowing: Not a normal route of entry. · Information for doctor: · Most important symptoms and effects, both acute and delayed: No further relevant information available. · Indication of any immediate medical attention and special treatment needed No further relevant information available. * 5 Fire-fighting measures · Extinguishing media · Suitable extinguishing agents: Use fire fighting measures that suit the environment. (Contd. on page 3)

41.0

Page 3/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture Use water spray to cool fire-exposed containers. · Special hazards arising from the substance or mixture Closed containers may explode when exposed to extreme heat. If incinerated, product will releaset the following toxic fumes: Oxides of Carbon and Nitrogen (NOx). · Advice for firefighters This gas mixture is not flammable; however, containers, when involved in fire, may rupture or burst in the heat of the fire. · Protective equipment: As in any fire, wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent), and full protective gear to prevent contact with skin and eyes. * 6 Accidental release measures · Personal precautions, protective equipment and emergency procedures Treat any fumes as toxic. In a confined area, NIOSH approved respiratory protection may be required. · Environmental precautions: Inform authorities in case of gas release. · Methods and material for containment and cleaning up: Dispose contaminated material as waste according to section 13. Ensure adequate ventilation. Dispose of the collected material according to regulations. · Reference to other sections See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information. * 7 Handling and storage · Handling: · Precautions for safe handling Ensure good ventilation/exhaustion at the workplace. Open and handle receptacle with care. Be aware of any signs of dizziness or fatigue; exposures to fatal concentrations of this gas mixture could occur without any significant warning symptoms due to the potential for oxygen deficiency (simple asphyxiation). Do not attempt to adjust, repair or in any other way modify the cylinders containing this gas mixture. If there is a malfunction or another type of operational problem, contact nearest distributor immediately. · Information about protection against explosions and fires: Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50 °C, i.e. electric lights. Do not pierce or burn, even after use. Keep protective respiratory device available. Do not cut, grind or weld on container that contains or contained product. Do not spray on a naked flame or any incandescent material. · Conditions for safe storage, including any incompatibilities Store away from strong oxidizing agents, phosphorous, organic materials and powdered metals. · Storage: · Requirements to be met by storerooms and receptacles: Store in a cool location. Cylinders should be firmly secured to prevent falling or being knocked over. Cylinders must be protected from the environment, and preferably kept at room temperature. Cylinders should be stored in dry, well-ventilated areas, away from sources of heat, ignition, and direct sunlight. Protect cylinders against physical damage. Full and empty cylinders should be segregated. Use a "first-on, first-out" inventory system to prevent full containers from being stored for long periods of time. (Contd. on page 4)

41.0

Page 4/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture · Information about storage in one common storage facility: Not required. · Further information about storage conditions: Store in cool, dry conditions in well sealed receptacles. · Specific end use(s) No further relevant information available. * 8 Exposure controls/personal protection · Additional information about design of technical systems: No further data; see section 7. · Control parameters All ventilation should be designed in accordance with OSHA standard (29 CFR 1910.94). Use mechanical (general) ventilation for storage areas. Use appropriate ventilation as required to keep Exposure Limits in Air below TLV & PEL limits. · Components with occupational exposure limits: 7727-37-9 Nitrogen TLV withdrawn TLV, see App. F; simple asphyxiant 74-82-8 Methane TLV refer to Appendix F, 1000ppm · Additional information: The lists that were valid during the creation of this SDS were used as basis. · Exposure controls · Personal protective equipment: · General protective and hygienic measures: Keep away from foodstuffs, beverages and feed. Wash hands before breaks and at the end of work. · Breathing equipment: Not necessary if room is well-ventilated. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure, use respiratory protective device that is independent of circulating air. · Eye protection: Not necessary under normal conditions. * 9 Physical and chemical properties · Information on basic physical and chemical properties · General Information · Appearance: Gaseous Form: Clear, colorless Color: · Odor: Odorless · Odor threshold: Not determined. · pH-value:

Not determined.

· Change in condition Melting point/Melting range: Boiling point/Boiling range:

Not determined. -195 °C (-319 °F)

· Flash point:

Not applicable.

· Flammability (solid, gaseous):

Not determined.

· Ignition temperature: Decomposition temperature: · Auto igniting:

Not determined. Product is not self-igniting. (Contd. on page 5)

41.0

Page 5/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture

· Danger of explosion:

Not determined.

· Explosion limits: Lower: Upper:

Not determined. Not determined.

· Vapor pressure:

Not determined.

· Density @ 20 °C (68 °F): · Relative density · Vapor density · Evaporation rate

0.026 g/cm³ (0.217 lbs/gal) Not determined. Not determined. Not applicable.

· Solubility in / Miscibility with Water:

Not miscible or difficult to mix.

· Partition coefficient (n-octanol/water): Not determined. · Viscosity: Dynamic: Kinematic:

Not determined. Not determined.

· Solvent content: Organic solvents: · Other information

0.0 % No further relevant information available.

* 10 Stability and reactivity · Reactivity No further relevant information available. · Chemical stability Stable under normal conditions. · Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications. · Possibility of hazardous reactions No dangerous reactions known. · Conditions to avoid No further relevant information available. · Incompatible materials: Strong oxidizing agents, phosphorous, organic materials and powdered metals. · Hazardous decomposition products: Carbon Oxides and Nitrogen Oxides (NOx). * 11 Toxicological information · Information on toxicological effects The toxicity of this product is unknown. · Acute toxicity: · Primary irritant effect: · on the skin: No irritating effect. · on the eye: No irritating effect. · Additional toxicological information: The product shows the following dangers according to internally approved calculation methods for preparations: Harmful · Carcinogenic categories · IARC (International Agency for Research on Cancer) Group 1 - Carcinogenic to humans Group 2A - Probably carcinogenic to humans Group 2B - Possibly carcinogenic to humans Group 3 - Not classifiable as to its carcinogenicity to humans Group 4 - Probably not carcinogenic to humans None of the ingredients are listed. (Contd. on page 6)

41.0

Page 6/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture · NTP (National Toxicology Program) None of the ingredients are listed. · OSHA-Ca (Occupational Safety & Health Administration) None of the ingredients are listed. * 12 Ecological information · Toxicity The hazards for the aquatic environment are unknown. · Aquatic toxicity: No further relevant information available. · Persistence and degradability No further relevant information available. · Behavior in environmental systems: · Bioaccumulative potential No further relevant information available. · Mobility in soil No further relevant information available. · Additional ecological information: · General notes: Generally not hazardous for water. · Results of PBT and vPvB assessment · PBT: Not applicable. · vPvB: Not applicable. · Other adverse effects No further relevant information available. * 13 Disposal considerations · Waste treatment methods · Recommendation: Release all residual gas pressure in a well ventilated area. Verify the cylinder is completely empty (0 PSIG). Remove or cover any hazard labels. Return empty cylinder for recycling. NOTE: Check with the local easte authority before placing any gas cylinder into waste container for pickup. GASCO encourages the consumer to return all cylinders. · Waste disposal key: The U.S. EPA has not published waste disposal numbers for this product's components. · Uncleaned packagings: · Recommendation: Return cylinder and unused product to supplier.

14 Transport information · UN-Number · DOT, ADR, IMDG, IATA · UN proper shipping name · DOT · ADR · IMDG, IATA · Transport hazard class(es)

UN1956 Compressed gas, n.o.s. UN1956 Compressed gas, n.o.s. COMPRESSED GAS, N.O.S.

· DOT

· Class

2.2 (Contd. on page 7)

41.0

Page 7/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture · Label

2.2

· ADR

· Class · Label

2.2 1A 2.2

· IMDG, IATA

· Class 2.2 · Label 2.2 · Packing group · DOT, ADR, IMDG, IATA Non-Regulated Material · Environmental hazards: Not applicable. · Special precautions for user Not applicable. · Danger code (Kemler): 20 · EMS Number: F-C,S-V · Transport in bulk according to Annex II of Not applicable. MARPOL73/78 and the IBC Code · Transport/Additional information: · DOT · Quantity limitations · ADR · Excepted quantities (EQ)

· IMDG · Limited quantities (LQ) · Excepted quantities (EQ) · UN "Model Regulation":

On passenger aircraft/rail: 75 kg On cargo aircraft only: 150 kg Code: E1 Maximum net quantity per inner packaging: 30 ml Maximum net quantity per outer packaging: 1000 ml 120 ml Code: E1 Maximum net quantity per inner packaging: 30 ml Maximum net quantity per outer packaging: 1000 ml UN1956, Compressed gas, n.o.s., 2.2

* 15 Regulatory information · Safety, health and environmental regulations/legislation specific for the substance or mixture · Sara · Section 355 (extremely hazardous substances): None of the ingredients are listed. · Section 313 (Specific toxic chemical listings): None of the ingredients are listed. (Contd. on page 8)

41.0

Page 8/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture · TSCA (Toxic Substances Control Act): All ingredients are listed. · California Proposition 65 · Chemicals known to cause cancer: None of the ingredients are listed. · Chemicals known to cause reproductive toxicity for females: None of the ingredients are listed. · Chemicals known to cause reproductive toxicity for males: None of the ingredients are listed. · Chemicals known to cause developmental toxicity: None of the ingredients are listed. · Carcinogenic categories · EPA (Environmental Protection Agency) None of the ingredients are listed. · TLV (Threshold Limit Value established by ACGIH) None of the ingredients are listed. · NIOSH-Ca (National Institute for Occupational Safety and Health) None of the ingredients are listed. · GHS label elements The product is classified and labeled according to the Globally Harmonized System (GHS). · Hazard pictograms

GHS04 · Signal word Warning · Hazard-determining components of labeling: Nitrogen Methane · Hazard statements Contains gas under pressure; may explode if heated. · Precautionary statements Protect from sunlight. Store in a well-ventilated place. · National regulations: The product is subject to be classified according with the latest version of the regulations on hazardous substances. · State Right to Know CAS: 7727-37-9 Nitrogen RTECS: QW 9700000 CAS: 7782-44-7 Oxygen CAS: 74-82-8 Methane RTECS: PA 1490000 All ingredients are listed.

Press. Gas, H280; Simple Asphyxiant Oxid. Gas 1, H270; Press. Gas, H280 Flam. Gas 1, H220; Press. Gas, H280

75.6 - 97.9999% 2 - 20.9% 0.0001 - 3.5%

(Contd. on page 9)

41.0

Page 9/9

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03.

Issue date 06/11/2015

Reviewed on 06/11/2015

Trade name: Precision Calibration Gas Mixture · Chemical safety assessment: A Chemical Safety Assessment has not been carried out. * 16 Other information · Relevant phrases Gasco Affiliates, LLC, makes not express or implied warranties, guarantees or representations regarding the product of the information herein, including but not limited to any implied warranty or merchantability or fitness for use. Gasco Affilitates, LLC shall not be liable for any personal injury, property or other damages of any nature, whether compensatory, consequential, exemplary, or otherwise, resulting from any publication, use of reliance upon the information herein. · Date of preparation / last revision 06/11/2015 / · Abbreviations and acronyms: ADR: The European Agreement concerning the International Carriage of Dangerous Goods by Road ADN: The European Agreement concerning the International Carriage of Dangerous Goods by Inland Waterways IMDG: International Maritime Code for Dangerous Goods DOT: US Department of Transportation IATA: International Air Transport Association ACGIH: American Conference of Governmental Industrial Hygienists EINECS: European Inventory of Existing Commercial Chemical Substances ELINCS: European List of Notified Chemical Substances CAS: Chemical Abstracts Service (division of the American Chemical Society) NFPA: National Fire Protection Association (USA) HMIS: Hazardous Materials Identification System (USA) Flam. Gas 1: Flammable gases, Hazard Category 1 Oxid. Gas 1: Oxidising Gases, Hazard Category 1 Press. Gas: Gases under pressure: Compressed gas

· * Data compared to the previous version altered. SDS created by MSDS Authoring Services www.msdsauthoring.com

+1-877-204-9106

Loading...

Safety Data Sheet (SDS)

41.0 Page 1/9 Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g) and GHS Rev 03. Issue date 06/11/2015 Reviewed on 06/11/2015 * 1 I...

109KB Sizes 2 Downloads 25 Views

Recommend Documents

Safety Data Sheet (SDS) - ENMET
Details of the supplier of the safety data sheet. · Manufacturer/Supplier: Gasco Affiliates, LLC. 320 Scarlett Blvd. Ol

Safety Data Sheet (SDS) - Detcon
May 29, 2015 - Details of the supplier of the safety data sheet .... As in any fire, wear self-contained breathing appar

American Orthodontics | Safety Data Sheet - SDS
... Phosphoric Acid (42K) – Trade Names: Acid Etching Gel, Acid Etching Gel Liquid, Acid Etching Gel Semi-Gel; Glass I

Material Safety Data Sheet
May 25, 2015 - Date of previous issue: 11/24/2013. United States. Material Safety Data Sheet. The Ortho Group. P.O. Box

safety data sheet - MANNOL
601-. 808-1. 12179-04-3 01-2119492616-28. Boric acid, disodium salt, pentahydrate substance listed as REACH. Candidate.

Safety Data Sheet - DENTAURUM
Jan 27, 2017 - REACH No. Classification according to Regulation (EC) No. 1272/2008 [CLP]. 12179-04-3 disodium tetraborat

Safety data sheet
Nov 23, 2015 - CAS: 12179-04-3. EINECS: 215-540-4 disodium tetraborate pentahydrate. Repr. 1B, H360FD;. Eye Dam. 1, H318

safety data sheet - Airgas
Oct 15, 2014 - n-Butane; Diethyl; Freon 600; Liquefied petroleum gas; LPG; n-C4H10; Butanen;. Butani; Methylethylmethane

MATERIAL SAFETY DATA SHEET
Product and Company Identification. Material name. 5000-Sc Cleaning Solution. Revision date. 03-08-2011. Version #. 01.

Safety Data Sheet - Cristal
Sep 27, 2012 - ... Class 2 IMO REQUIREMENTS: Ems No.: 2-08 MFAG Table No.: 740 Marine Pollutant IMDG Code Page: 2116. Ch