kWh meters WQR96 MKII, WQ2R96 MKII, WQR96-x MKII, WQR96-c MKII • Accuracy class 1.0 (EN 62053-21) • For single-phase and 3-phase networks • Microprocessor-controlled meters with pulse output (SO) • Simultaneous measurement of two quantities (except type WQR96 MKII) • 60 to 400 V AC aux. power supply • Complies with Electricity metering equipment standard (IEC 62052-11)

Document no.: 4921210157B

Data sheet

kWh meters, WQR96 MKII

Application The kWh meters types WQR96 MKII and WQ2R96 MKII are intended for energy measurement in single-phase and 3phase networks, providing a class 1.0 measurement of the imported or exported energy. The meters are microprocessorcontrolled and equipped with a 7-digit electromechanical counter, which retains the reading in case of supply voltage failure. The meters are furthermore equipped with one or two pulse outputs. The meters can be adapted to the applied current transformers. WQR96 MKII

Meter with a 7-digit register and one pulse output for measurement of one type of energy only (kWh or kvarh).

WQ2R96 MKII

Meter with two 7-digit registers and two pulse outputs for measurement of two types of energy (both kWh and kvarh imported or exported).

WQR96-x MKII

Meter with both a 7-digit register and one pulse output for energy measurement (kWh or kvarh) and a 90° instrument for simultaneous indication of the momentary power value (active or reactive).

WQR96-c MKII

Meter with both a 7-digit register and one pulse output for energy measurement (kWh or kvarh) and a 240° instrument for simultaneous indication of the momentary power value (active or reactive).

Technical specifications Auxiliary voltage

60, 100, 230, 400 V AC ±20 %

Rated frequency

45 to 65 Hz

Wire

Multi-stranded: 1.5 mm 2 Single-stranded: 2.5 mm

2

Measuring specifications Meas. voltage Un

Ph-N 400 V AC Ph-Ph 690 V AC, range +/-20 % Consumption: <0.1 VA per phase Overload capacity: 1.5 × Un continuously 2 × Un for 10 s

Meas. current In

-/1 A or -/5 A, range 0 to 1.6 × In Consumption: <0.1 VA per phase Overload capacity: 3 × In continuously 25 × In for 3 s 50 × In for 1 s

Meas. frequency

50/60 Hz, range 16 to 400 Hz Energy: Active energy EN62053-21: Class 1. Reactive energy EN62053-23: Class 2 Power: 1.5 % of scale at nominal temperature range 10 to 30 °C. Outside this range, 3 % of scale

Accuracy

Output and counter specifications Relay outputs

Max. 250 V (AC), max. 100 V (DC)

Contact rating

AC: 250 V - 6 A - 1500 VA (250 V AC - 6 A resistive AC load 100,000 operations) DC: 35 V - 6 A - 210 W (30 V DC - 6 A resistive load 500,000 operations) Pulse duration: 100 ms No. of outputs: 2

Electromechanical counter

7 digits, each 4 × 1.2 mm

Pulse

1, 10 or 100 pulses per kWh (or MWh) Max. pulses per hour: 4000 Pulse duration: 100 ms

Isolation

1000 V (AC) between open contacts 4000 V (AC) between coil and contacts

DEIF A/S

Page 2 of 5

Data sheet

kWh meters, WQR96 MKII

Type test specifications Temperature

-10 to 55 °C (operating) -25 to 70 °C (storage)

IEC/EN 62052-11

Climate

Relative humidity ≤75 %

IEC/EN 62052-11

Vibration

3 to 13.2 Hz: 2 mmpp 13.2 to 100 Hz: 0.7 g

IEC/EN 60068-2-6 & IACS UR E10

Shock

50 g, 11 ms, half sine Tested with 3 impacts in each direction in all 3 axes In total 18 impacts per test

IEC/EN 60068-2-27, test Ea

Safety

Installation cat. III 600 V/cat. II 300 V Pollution degree 2 Tested to 2210 volt

IEC/EN 61010-1 tested at 50 Hz,1 min Each galvanic group tested to other galvanic groups and to protection earth

EMC

IEC/EN 62052-11 IEC/EN 60533 power distr. zone IACS UR E10 power distr. zone

Materials

All plastic parts are self-extinguishing

UL94 (V0)

Protection

Front: IP52 (IP66 optional by gasket) Housing/terminals: IP20

IEC/EN 60529

Approvals

See DEIF homepage for valid approval

www.deif.com

DEIF A/S

Page 3 of 5

Data sheet

kWh meters, WQR96 MKII

Connection diagrams

2W3 − three-wire, unbalanced load

1W4 − four-wire, balanced load

1W3 − three-wire, balanced load

3W4 − four-wire, unbalanced load

1W − single-wire

Terminals Inputs/quantities AC current Measuring inputs AC voltage

Auxiliary power supply

Output modules

DEIF A/S

Output

Terminals IL1

CT1 (1-3) (k-l)

IL2

CT2 (4-6) (k-l)

IL3

CT3 (7-9) (k-l)

UL1

2 (L1)

UL2

5 (L2)

UL3

8 (L3)

N

11

+/ACL

13

–/ACN

14

Out −1

15

C−12

16

Out −2

17

Page 4 of 5

Data sheet

kWh meters, WQR96 MKII

Dimensions in mm/auxiliary voltage/output connections

Order specifications WQR96 MKII/WQ2R96 MKII Examples: Type

AUX

Connection

VT ratio

CT ratio

Counter(s)

Relay 1 (2)

Relay 2

WQR96

60

1W3

10,000/100 V

100/1 A

10p/Mvarh

10p/Mvarh

-

WQ2R96

100

3W4

10,000/100 V

50/1 A

1p/MWh E*/MWh I* 1p/MWh

1p/MWh

* : E = exported energy I = imported energy WQR96-x MKII/WQR96-c MKII Examples: Type

AUX

Connection

VT ratio

CT ratio

Counter

Relay 1 & 2

Scale

WQR96-x

230

3W4

10,000/400 V

100/5 A

10p/MWh

10p/MWh

0 to 2 MW

WQR96-c

400

3W4

10,000/100 V

200/5 A

1p/MWh

1p/MWh

0 to 4 MW

Note: If there is no VT, the pulse duration is normally 1, 10 or 100p/kWh/kvarh.

Due to our continuous development we reserve the right to supply equipment which may vary from the described. DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: [email protected], URL: www.deif.com

Loading...

DATA SHEET

TCM-2 Thyristor Control Module TCM-2 Thyristor Control DATA SHEETModule DATA SHEET DATA SHEET kWh meters WQR96 MKII, WQ2R96 MKII, WQR96-x MKII, WQR96...

510KB Sizes 26 Downloads 11 Views

Recommend Documents

Data sheet
start of lifetime: 66 W, end of lifetime: 66 W, reduction: 33 W, luminaire housing, of diecast aluminium, powder-coated,

Data sheet
Jan 24, 2013 - Acceptance standard. None; tolerances to ISO 9906. Class 2A / 3B; below 10 kW acc. to paragraph 4.4.2. Wa

DATA SHEET
April 2017. ITEM. PART NUMBERS. DESCRIPTION. QTY. 5CP6120. 5CP6120CSSG1. MATL. 283. 34334. —. Kit, Oil Drain (3/8” x

PIC16F84A Data Sheet - Microchip
High Performance RISC CPU Features: • Only 35 single word instructions to learn. • All instructions single-cycle exc

Major Works Data Sheet
Albert Camus was born in French colonial. Algiers. His father was killed in WWI, and he, his brother, mother, grandmothe

safety data sheet - Betco
Precautionary statements. Prevention. : Wear protective gloves: < 1 hour (breakthrough time): disposable vinyl. Wear eye

data sheet - Digital Fire
DESCRIPTION. HFC-227ea provides superior fire protection in a wide range of applications from sensitive electrical equip

Material Safety Data Sheet
Nov 24, 2013 - United States. Material Safety Data Sheet. The Ortho Group. P.O. Box 190. Marysville, Ohio 43040. United

Data Sheet - Seagate
Yes. Rescue Recovery Option. 3-Year Option. Yes. Yes. Yes. Performance. Spin Speed. 7200RPM. 7200RPM. 5900RPM. Cache. 25

Safety Data Sheet - Bizol
Jan 28, 2015 - 10 - < 20 %. 203-473-3. 603-027-00-1. 01-2119456816-28. Acute Tox. 4, STOT RE 2; H302 H373. 12179-04-3 di

3 | Watch now! | Sleepy Hollow