Data sheet PE 81.01

Loading...

Electronic pressure measurement

High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4

Applications ■■ Machine building

■■ Hydraulics and pneumatics ■■ Pumps

■■ Chemical industry

Special features ■■ Measuring ranges from 0 ... 0.1 to 0 ... 1,000 bar ■■ Non-linearity 0.2 % of span (BFSL)

■■ Output signals: 4 ... 20 mA, DC 0 ... 10 V, DC 0 ... 5 V and

others

■■ Electrical connections: Angular connector form A, circular

connector M12 x 1, various cable outlets and others ■■ Zero point and span adjustable via internal potentiometer

Pressure transmitter model S-10

Description The model S-10 pressure transmitter for general industrial applications is the ideal solution for customers with demanding measuring requirements. It features a very good accuracy, a robust design and an exceptional number of variants, meaning it can be suited to the widest range of applications. Versatile The model S-10 offers continuous measuring ranges between 0 ... 0.1 and 0 ... 1,000 bar in all the major units. These measuring ranges can be combined in almost any way with all the standard industry output signals, the most common international process connections and a wide number of electrical connections. Furthermore, it offers numerous options, such as different accuracy classes, extended temperature ranges and customer-specific pin assignments.

High quality The robust design turns the model S-10 into a very high quality product, which even the most adverse environmental conditions cannot affect. Whether with the lowest temperatures when used outdoors, with extreme shock and vibration in machine building or with aggressive media in the chemical industry, this transmitter can meet all requirements. Availability All variants described in this data sheet are available on very short lead times. For particularly urgent demands, there is a sizeable stock available.

WIKA data sheet PE 81.01 ∙ 09/2017 Data sheets showing similar products: Pressure transmitter for general industrial applications; model A-10; see data sheet PE 81.60 OEM pressure transmitter for general industrial applications; model O-10; see data sheet PE 81.65 Flush pressure transmitter for viscous and solids-containing media; model S-11; see data sheet PE 81.02

Page 1 of 9

Measuring ranges Relative pressure bar

Measuring range

Overload safety

Measuring range

Overload safety

Measuring range

psi

0 ... 60

0 ... 4

0 ... 6

17

0 ... 10

35

0 ... 100

35

0 ... 160

0 ... 250

0 ... 0.6

4

0 ... 16

0 ... 1

0 ... 1.6

5

10

0 ... 25

80

0 ... 40

50

0 ... 400

80

0 ... 600

0 ... 1,000

320

500

800

1,200

1,500

Measuring range

0 ... 5

0 ... 10

0 ... 15

0 ... 20

0 ... 25

0 ... 30

0 ... 50

Overload safety

29

29

72.5

145

145

145

240

Measuring range

0 ... 60

0 ... 100

0 ... 150

0 ... 160

0 ... 170

0 ... 200

0 ... 250

Overload safety

240

500

500

1,160

1,160

1,160

1,160

Measuring range

0 ... 300

0 ... 400

0 ... 500

0 ... 600

0 ... 750

0 ... 800

0 ... 1,000

Overload safety

1,160

1,160

1,160

1,160

1,740

1,740

1,740

Measuring range

0 ... 1,500

0 ... 1,600

0 ... 2,000

0 ... 3,000

0 ... 4,000

0 ... 5,000

0 ... 6,000

Overload safety

2,900

4,600

4,600

7,200

7,200

11,600

11,600

0 ... 1.6

0 ... 2.5

0 ... 4

Measuring range

Overload safety

Measuring range

Overload safety

Measuring range

Overload safety

0 ... 7,500

0 ... 8,000

Measuring range

Overload safety

Measuring range

0 ... 10,000

0 ... 15,000

17,400

17,400

17,400

21,700

0 ... 0.25

0 ... 0.4

0 ... 0.6

0 ... 1

2

0 ... 6

35

0 ... 15

72.5

2

0 ... 10

35

0 ... 25

145

Vacuum and +/- measuring range

-0.6 ... 0

4

-1 ... 0

4

5

0 ... 16

0 ... 25

80

80

0 ... 50

0 ... 100

240

500

-0.4 ... 0

-0.25 ... 0

2

2

10

10

0.8 ... 1.2

0 ... 250

1,160

-0.16 ... 0

-0.1 ... 0

-1 ... +3

-1 ... +5

-30 inHg ... +60

1.5

5

10

-1 ... +0.6

-1 ... +1.5

Measuring range

-1 ... +9

-1 ... +15

-1 ... +24

Measuring range

- 15 inHg ... 0

-30 inHg ... 0

-30 inHg ... +15

-30 inHg ... +30 -30 inHg ... +300

35

80

10

Overload safety

72.5

72.5

145

-30 inHg ... +100

-30 inHg ... +160

-30 inHg ... +200

500

1,160

17

1

35

50

Measuring range

Overload safety

17

5

Overload safety Overload safety psi

0 ... 0.4

2

200

Absolute pressure

bar

0 ... 0.25

2

120

Measuring range

psi

0 ... 2.5

10

0 ... 0.16

1.5

Overload safety

Overload safety

bar

0 ... 0.1

1

1,160

240

240

1,160

The given measuring ranges are also available in kg/cm2 and MPa. Vacuum tightness Yes

Page 2 of 9

WIKA data sheet PE 81.01 ∙ 09/2017

Output signals Signal type

Current (2-wire)

Accuracy specifications Signal

4 ... 20 mA 20 ... 4 mA

Current (3-wire)

0 ... 20 mA

Voltage (3-wire)

DC 0 ... 10 V DC 0 ... 5 V DC 1 ... 5 V DC 0.5 ... 4.5 V ratiometric

Non-linearity (per IEC 61298-2) ≤ ± 0.2 % of span BFSL Non-repeatability ≤ 0.1 % of span Accuracy at reference conditions Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2).

Other output signals on request.

Accuracy

Load in Ω ■■ Current output (2-wire): ≤ (power supply - 10 V) / 0.02 A

Standard

≤ ±0.50 % of span

Option

≤ ±0.25 % of span 1)

■■ Current output (3-wire):

≤ (power supply - 3 V) / 0.02 A

■■ Voltage output (3-wire):

> maximum output signal / 1 mA

1) Only for measuring ranges ≥ 0.25 bar

Adjustability of zero point and span Adjustment is made using potentiometers inside the instrument. ■■ Zero point: ± 5 % ■■ Span: ±5% Temperature error at 0 ... 80 °C

■■ Mean temperature coefficient of zero point:

Voltage supply Power supply The power supply depends on the selected output signal ■■ 4 ... 20 mA: DC 10 ...30 V ■■ 20 ... 4 mA: DC 10 ...30 V ■■ 0 ... 20 mA: DC 10 ...30 V ■■ DC 0 ... 5 V: DC 10 ...30 V ■■ DC 1 ... 5 V: DC 10 ...30 V ■■ DC 0 ... 10 V: DC 14 ... 30 V ■■ DC 0.5 ... 4.5 V ratiometric: DC 4.5 ...5.5 V

- Measuring ranges ≤ 0.25 bar: ≤ 0.4 % of span/10 K - Measuring ranges > 0.25 bar: ≤ 0.2 % of span/10 K

■■ Mean temperature coefficient of span:

≤ 0.2 % of span/10 K

Long-term stability at reference conditions ≤ ±0.2 % of span/year

Reference conditions (per IEC 61298-1)

Time response

Temperature 15 ... 25 °C

■■ ≤ 1 ms

Atmospheric pressure 860 ... 1,060 mbar

Settling time

■■ ≤ 2 ms for output signal DC 0.5…4.5 V ratiometric and

measuring ranges < 400 mbar, 10 psi

Humidity 45 ... 75 % r. h. Power supply DC 24 V Mounting position Calibrated in vertical mounting position with pressure connection facing downwards.

WIKA data sheet PE 81.01 ∙ 09/2017

Page 3 of 9

Operating conditions Ingress protection (per IEC 60529) For ingress protections see "Electrical connections" The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection Vibration resistance (per IEC 60068-2-6) 20 g Shock resistance (per IEC 60068-2-27) 1,000 g (mechanical) Permissible temperature ranges Medium

Ambient

Storage

Standard

-30 ... +100 °C

Option

-40 ... +125 °C

-20 ... +80 °C

-20 ... +80 °C

-40 ... +100 °C

-40 ... +100 °C

Process connections Standard

Thread size

EN 837

G¼B G½B

DIN 3852-E

G ¼ A 1)

ANSI/ASME B1.20.1

¼ NPT ½ NPT

SAE J514 E

7/16-20 UNF with 74° taper

-

G ½ male / G ¼ female

-

G ¼ female

-

M20 x 1.5

ISO 7



1) Maximum overload safety 600 bar

Other process connections on request

Materials Wetted parts Stainless steel Non-wetted parts

■■ Case: Stainless steel

■■ Internal pressure transmission medium: Synthetic oil ■■ Clamping nut: PA

■■ Angular connector: PA

■■ O-rings at the clamping nut: NBR ■■ Flat gasket: VMQ

Instruments with a measuring range of > 25 bar relative do not contain any pressure transmission medium (dry measuring cell).

Page 4 of 9

WIKA data sheet PE 81.01 ∙ 09/2017

Electrical connections Electrical connection

Ingress Wire cross-section protection

Cable diameter

Cable lengths

6 ... 8 mm

-

-

-

IP65

max. 1.5 mm2

Angular connector DIN 175301-803 with ½ NPT

IP65

max. 1.5

mm2

IP67

-

-

-

Bayonet connector (6-pin)

IP67

-

-

-

IP67

3 x 0.5

mm2

6.8 mm

1.5 m, 3 m, 5 m, 10 m, 5 ft, 10 ft, 20 ft, 30 ft, others on request

■■ Standard

IP67

3 x 0.5 mm2

6.8 mm

1.5 m, 3 m, 5 m, 10 m, 5 ft, 10 ft, 20 ft, 30 ft, others on request

■■ not adjustable

IP68

3 x 0.5 mm2

6.8 mm

1.5 m, 3 m, 5 m, 10 m, 5 ft, 10 ft, 20 ft, 30 ft, others on request

■■ adjustable

IP68

3 x 0.5 mm2

6.8 mm

1.5 m, 3 m, 5 m, 10 m, 5 ft, 10 ft, 20 ft, 30 ft, others on request

Angular connector DIN 175301-803 A

Circular connector M12 x 1 (4-pin)

½ NPT conduit male, with cable outlet Cable outlet

Short-circuit resistance S+ vs. UReverse polarity protection U+ vs. UOvervoltage protection DC 36 V Insulation voltage DC 500 V Connection diagrams Angular connector DIN 175301-803 A 2-wire

3-wire

U+

1

1

U-

2

S+

-

Angular connector DIN 175301-803 A

2-wire

3-wire

U+

A

A

2

U-

B

B

3

S+

-

C

2-wire

3-wire

U+

1

1

U-

2

S+

-

Circular connector M12 x 1 (4-pin)

Bayonet connector (6-pin)

½ NPT conduit male, with cable outlet 2-wire

3-wire

U+

red (RD)

red (RD)

2

U-

black (BK)

black (BK)

3

S+

-

brown (BN)

2-wire

3-wire

Cable outlets

2-wire

3-wire

U+

1

1

U+

brown (BN)

brown (BN)

U-

3

3

U-

green (GN)

green (GN)

S+

-

4

S+

-

white (WH)

Shield

grey (GY)

grey (GY)

WIKA data sheet PE 81.01 ∙ 09/2017

Page 5 of 9

Logo

-

-

Description

Country

EU declaration of conformity ■■ EMC directive EN 61326 emission (group 1, class B) and interference immunity (industrial application) ■■ Pressure equipment directive ■■ RoHS directive

European Union

CSA Safety (e.g. electr. safety, overpressure, ...)

Canada

EAC EMC directive

Eurasian Economic Community

GOST Metrology, measurement technology

Russia

KazInMetr Metrology, measurement technology

Kazakhstan

MTSCHS Permission for commissioning

Kazakhstan

BelGIM Metrology, measurement technology

Belarus

UkrSEPRO Metrology, measurement technology

Ukraine

Uzstandard Metrology, measurement technology

Uzbekistan

CRN Safety (e.g. electr. safety, overpressure, ...)

Canada

Manufacturer‘s information and certifications Logo -

Description

China RoHS directive

Approvals and certificates, see website

Page 6 of 9

WIKA data sheet PE 81.01 ∙ 09/2017

Dimensions in mm Pressure transmitter model S-10 with angular connector DIN 175301-803 A

with angular connector DIN 175301-803 with ½ NPT

with circular connector M12 x 1 (4-pin)

Weight: approx. 0.2 kg

Weight: approx. 0.2 kg

Weight: approx. 0.2 kg

with bayonet connector (6-pin)

with ½ NPT conduit male, with cable outlet

with cable outlet, standard

Weight: approx. 0.2 kg

Weight: approx. 0.2 kg

Weight: approx. 0.2 kg

with cable outlet, not adjustable

with cable outlet, adjustable

Weight: approx. 0.2 kg

Weight: approx. 0.2 kg

WIKA data sheet PE 81.01 ∙ 09/2017

Page 7 of 9

Process connections

G

L1

G¼A

G1

G½B

12

G2



L1 20

G

L1

G

L1

G½B

20

½ NPT

19

M20 x 1,5

20



13

G¼B

L2

15,5

L3 13

G

G ¼ female

13

D1 25

L1

20

¼ NPT

L2

15

L3

13

G

12

7/16-20 UNF with 74° taper

L1

15

For information on tapped holes and welding sockets, see Technical Information IN 00.14 at www.wika.com.

Accessories and spare parts Mating connector Description

Order number

without cable

with 2 m cable

with 5 m cable

■■ with cable gland, metric

11427567

11225793

11250186

■■ with cable gland, conduit

11022485

-

-

■■ straight

2421262

11250780

11250259

■■ angled

2421270

11250798

11250232

Angular connector DIN 175301-803 A

Circular connector M12 x 1 (4-pin)

Sealings for mating connectors Mating connector

Angular connector DIN 175301-803 A

Order number 1576240

Sealings for process connection Thread size

Order number

Cu

Stainless steel

NBR

FKM

G ½ B EN 837

11250861

11251042

-

-

-

-

1537857

1576534

M20 x 1.5

11250861

11251042

-

-

G ¼ B EN 837

G ¼ A DIN 3852-E

Page 8 of 9

11250810

11250844

-

-

WIKA data sheet PE 81.01 ∙ 09/2017

Ordering information Model / Measuring range / Output signal / Accuracy / Electrical connection / Medium temperature / Process connection

09/2017 EN

© 2012 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.

WIKA data sheet PE 81.01 ∙ 09/2017

Page 9 of 9

WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 [email protected] www.wika.de

Loading...

Data sheet PE 81.01

Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further...

387KB Sizes 2 Downloads 22 Views

Recommend Documents

Data sheet PE 81.02 - WIKA Alexander Wiegand SE & Co. KG
1,500. 0 ... 2,000. 0 ... 3,000. 0 ... 5,000. 0 ... 6,000. Overload safety. 1,740. 1,740. 2,900. 4,600. 7,200. 11,600. 1

Data sheet
start of lifetime: 66 W, end of lifetime: 66 W, reduction: 33 W, luminaire housing, of diecast aluminium, powder-coated,

Data sheet
Jan 24, 2013 - Acceptance standard. None; tolerances to ISO 9906. Class 2A / 3B; below 10 kW acc. to paragraph 4.4.2. Wa

DATA SHEET
April 2017. ITEM. PART NUMBERS. DESCRIPTION. QTY. 5CP6120. 5CP6120CSSG1. MATL. 283. 34334. —. Kit, Oil Drain (3/8” x

DATA SHEET
Application. The kWh meters types WQR96 MKII and WQ2R96 MKII are intended for energy measurement in single-phase and 3-

PIC16F84A Data Sheet - Microchip
High Performance RISC CPU Features: • Only 35 single word instructions to learn. • All instructions single-cycle exc

Major Works Data Sheet
Albert Camus was born in French colonial. Algiers. His father was killed in WWI, and he, his brother, mother, grandmothe

safety data sheet - Betco
Precautionary statements. Prevention. : Wear protective gloves: < 1 hour (breakthrough time): disposable vinyl. Wear eye

data sheet - Digital Fire
DESCRIPTION. HFC-227ea provides superior fire protection in a wide range of applications from sensitive electrical equip

Material Safety Data Sheet
Nov 24, 2013 - United States. Material Safety Data Sheet. The Ortho Group. P.O. Box 190. Marysville, Ohio 43040. United

Deadwood | Modded Flash Section | Read More